thigh-based actigraph Search Results


90
ActiGraph llc thigh-based actigraph
Thigh Based Actigraph, supplied by ActiGraph llc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/thigh-based actigraph/product/ActiGraph llc
Average 90 stars, based on 1 article reviews
thigh-based actigraph - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
ActiGraph llc actigraph gt3x+ accelerometer
Methods based on mounted equipment to calculate energy expenditure of different activities.
Actigraph Gt3x+ Accelerometer, supplied by ActiGraph llc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/actigraph gt3x+ accelerometer/product/ActiGraph llc
Average 90 stars, based on 1 article reviews
actigraph gt3x+ accelerometer - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
ActiGraph llc wrist-based activity monitor
Methods based on mounted equipment to calculate energy expenditure of different activities.
Wrist Based Activity Monitor, supplied by ActiGraph llc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/wrist-based activity monitor/product/ActiGraph llc
Average 90 stars, based on 1 article reviews
wrist-based activity monitor - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
ActiGraph llc hip-worn accelerometers
Methods based on mounted equipment to calculate energy expenditure of different activities.
Hip Worn Accelerometers, supplied by ActiGraph llc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/hip-worn accelerometers/product/ActiGraph llc
Average 90 stars, based on 1 article reviews
hip-worn accelerometers - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
ActiGraph llc actilife, version 6.13.4
Methods based on mounted equipment to calculate energy expenditure of different activities.
Actilife, Version 6.13.4, supplied by ActiGraph llc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/actilife, version 6.13.4/product/ActiGraph llc
Average 90 stars, based on 1 article reviews
actilife, version 6.13.4 - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
ActiGraph llc research-grade am
Methods based on mounted equipment to calculate energy expenditure of different activities.
Research Grade Am, supplied by ActiGraph llc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/research-grade am/product/ActiGraph llc
Average 90 stars, based on 1 article reviews
research-grade am - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
ActiGraph llc ag lfe
Methods based on mounted equipment to calculate energy expenditure of different activities.
Ag Lfe, supplied by ActiGraph llc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/ag lfe/product/ActiGraph llc
Average 90 stars, based on 1 article reviews
ag lfe - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
ActiGraph llc actigraph gt3x 38x37x18
Methods based on mounted equipment to calculate energy expenditure of different activities.
Actigraph Gt3x 38x37x18, supplied by ActiGraph llc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/actigraph gt3x 38x37x18/product/ActiGraph llc
Average 90 stars, based on 1 article reviews
actigraph gt3x 38x37x18 - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
PAL Technologies Ltd thigh-mounted activpal
Mean differences in sedentary pattern variables between <t> activPAL </t> and the 15-second epoch ActiGraph accelerometer processing methods (N = 902 days from 195 children)
Thigh Mounted Activpal, supplied by PAL Technologies Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/thigh-mounted activpal/product/PAL Technologies Ltd
Average 90 stars, based on 1 article reviews
thigh-mounted activpal - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
PAL Technologies Ltd activpal 35×53×7
Mean differences in sedentary pattern variables between <t> activPAL </t> and the 15-second epoch ActiGraph accelerometer processing methods (N = 902 days from 195 children)
Activpal 35×53×7, supplied by PAL Technologies Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/activpal 35×53×7/product/PAL Technologies Ltd
Average 90 stars, based on 1 article reviews
activpal 35×53×7 - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
ActiGraph llc activpal
Specifications of <t> activPAL </t> and ActiGraph GT3X+.
Activpal, supplied by ActiGraph llc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/activpal/product/ActiGraph llc
Average 90 stars, based on 1 article reviews
activpal - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
ActiGraph llc accelerometer (actigraph, actigraph llc, pensacola, fl, usa)
Specifications of <t> activPAL </t> and ActiGraph GT3X+.
Accelerometer (Actigraph, Actigraph Llc, Pensacola, Fl, Usa), supplied by ActiGraph llc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/accelerometer (actigraph, actigraph llc, pensacola, fl, usa)/product/ActiGraph llc
Average 90 stars, based on 1 article reviews
accelerometer (actigraph, actigraph llc, pensacola, fl, usa) - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

Image Search Results


Methods based on mounted equipment to calculate energy expenditure of different activities.

Journal: Sensors (Basel, Switzerland)

Article Title: Validation of Five Minimally Obstructive Methods to Estimate Physical Activity Energy Expenditure in Young Adults in Semi-Standardized Settings

doi: 10.3390/s150306133

Figure Lengend Snippet: Methods based on mounted equipment to calculate energy expenditure of different activities.

Article Snippet: This showed that CPM based linear equationfor a thigh-worn ActiGraph GT3X+ accelerometer was not a good predictor of changes in walking stairs intensity in this study.

Techniques: Software, Activity Assay

Scatter plots and linear regression equations between CPM of a thigh-mounted ActiGraph GT3X+ accelerometer and EE measured by indirect calorimetry of physical activity types.

Journal: Sensors (Basel, Switzerland)

Article Title: Validation of Five Minimally Obstructive Methods to Estimate Physical Activity Energy Expenditure in Young Adults in Semi-Standardized Settings

doi: 10.3390/s150306133

Figure Lengend Snippet: Scatter plots and linear regression equations between CPM of a thigh-mounted ActiGraph GT3X+ accelerometer and EE measured by indirect calorimetry of physical activity types.

Article Snippet: This showed that CPM based linear equationfor a thigh-worn ActiGraph GT3X+ accelerometer was not a good predictor of changes in walking stairs intensity in this study.

Techniques: Activity Assay

Mean differences in sedentary pattern variables between  activPAL  and the 15-second epoch ActiGraph accelerometer processing methods (N = 902 days from 195 children)

Journal: Journal of sports sciences

Article Title: Day-level sedentary pattern estimates derived from hip-worn accelerometer cut-points in 8-12 year olds: Do they reflect postural transitions?

doi: 10.1080/02640414.2019.1605646

Figure Lengend Snippet: Mean differences in sedentary pattern variables between activPAL and the 15-second epoch ActiGraph accelerometer processing methods (N = 902 days from 195 children)

Article Snippet: Children were asked to simultaneously wear a hip-mounted ActiGraph (GT3X+; Pensacola, FL, USA) and thigh-mounted activPAL (PAL Technologies Ltd, Glasgow, UK) for eight consecutive days during waking hours, except during water-based activities.

Techniques:

Mean differences in sedentary pattern variables between  activPAL  and the 60-second epoch ActiGraph processing methods (N = 902 days from 195 children)

Journal: Journal of sports sciences

Article Title: Day-level sedentary pattern estimates derived from hip-worn accelerometer cut-points in 8-12 year olds: Do they reflect postural transitions?

doi: 10.1080/02640414.2019.1605646

Figure Lengend Snippet: Mean differences in sedentary pattern variables between activPAL and the 60-second epoch ActiGraph processing methods (N = 902 days from 195 children)

Article Snippet: Children were asked to simultaneously wear a hip-mounted ActiGraph (GT3X+; Pensacola, FL, USA) and thigh-mounted activPAL (PAL Technologies Ltd, Glasgow, UK) for eight consecutive days during waking hours, except during water-based activities.

Techniques:

a. Agreement plots for sedentary pattern variables between activPAL and ActiGraph 100 counts per 60-seconds cut-point (N = 899 days from 195 children)

Journal: Journal of sports sciences

Article Title: Day-level sedentary pattern estimates derived from hip-worn accelerometer cut-points in 8-12 year olds: Do they reflect postural transitions?

doi: 10.1080/02640414.2019.1605646

Figure Lengend Snippet: a. Agreement plots for sedentary pattern variables between activPAL and ActiGraph 100 counts per 60-seconds cut-point (N = 899 days from 195 children)

Article Snippet: Children were asked to simultaneously wear a hip-mounted ActiGraph (GT3X+; Pensacola, FL, USA) and thigh-mounted activPAL (PAL Technologies Ltd, Glasgow, UK) for eight consecutive days during waking hours, except during water-based activities.

Techniques:

a. Agreement plots for sedentary pattern variables between activPAL and ActiGraph 300 counts per 60-seconds cut-point (N = 899 days from 195 children)

Journal: Journal of sports sciences

Article Title: Day-level sedentary pattern estimates derived from hip-worn accelerometer cut-points in 8-12 year olds: Do they reflect postural transitions?

doi: 10.1080/02640414.2019.1605646

Figure Lengend Snippet: a. Agreement plots for sedentary pattern variables between activPAL and ActiGraph 300 counts per 60-seconds cut-point (N = 899 days from 195 children)

Article Snippet: Children were asked to simultaneously wear a hip-mounted ActiGraph (GT3X+; Pensacola, FL, USA) and thigh-mounted activPAL (PAL Technologies Ltd, Glasgow, UK) for eight consecutive days during waking hours, except during water-based activities.

Techniques:

Specifications of  activPAL  and ActiGraph GT3X+.

Journal: Medicine and science in sports and exercise

Article Title: Ability of Thigh-Worn ActiGraph and activPAL Monitors to Classify Posture and Motion

doi: 10.1249/MSS.0000000000000497

Figure Lengend Snippet: Specifications of activPAL and ActiGraph GT3X+.

Article Snippet: When worn on the thigh, this could contribute to step count inaccuracy if actual step count was an outcome of interest. table ft1 table-wrap mode="anchored" t5 TABLE 1. caption a7 activPAL3 ActiGraph GT3X+ Physical Dimensions 5.3 cm × 3.5 cm × 0.7 cm 4.6 cm × 3.3 cm × 1.5 cm Weight 15 g 19 g Communication Five-port docking station with data transfer port Full-speed USB 2.0 Performance Transducer/sensor Capacitance-based accelerometer Triaxis solid-state accelerometer (ambient light photodiode) Dynamic range ±2 g ±6 g Sample rate 20 Hz 30–100 Hz in 10-Hz increments Resolution 8-bit A/D conversion 12-bit A/D conversion; 2.93 mG (raw data) Memory capacity 16 MB 512 MB Battery life 10 d 30 d (fully charged) Water resistance Can be waterproofed to allow wear in shower 1 m for 30 min Calibration Internal Internal Wear location Thigh Wrist, waist, ankle, and thigh Open in a separate window Specifications of activPAL and ActiGraph GT3X+.

Techniques: Battery

Monitor arrangement. ActiGraph and activPAL™ were worn on the front midline of the right thigh midway between the hip and the knee joint.

Journal: Medicine and science in sports and exercise

Article Title: Ability of Thigh-Worn ActiGraph and activPAL Monitors to Classify Posture and Motion

doi: 10.1249/MSS.0000000000000497

Figure Lengend Snippet: Monitor arrangement. ActiGraph and activPAL™ were worn on the front midline of the right thigh midway between the hip and the knee joint.

Article Snippet: When worn on the thigh, this could contribute to step count inaccuracy if actual step count was an outcome of interest. table ft1 table-wrap mode="anchored" t5 TABLE 1. caption a7 activPAL3 ActiGraph GT3X+ Physical Dimensions 5.3 cm × 3.5 cm × 0.7 cm 4.6 cm × 3.3 cm × 1.5 cm Weight 15 g 19 g Communication Five-port docking station with data transfer port Full-speed USB 2.0 Performance Transducer/sensor Capacitance-based accelerometer Triaxis solid-state accelerometer (ambient light photodiode) Dynamic range ±2 g ±6 g Sample rate 20 Hz 30–100 Hz in 10-Hz increments Resolution 8-bit A/D conversion 12-bit A/D conversion; 2.93 mG (raw data) Memory capacity 16 MB 512 MB Battery life 10 d 30 d (fully charged) Water resistance Can be waterproofed to allow wear in shower 1 m for 30 min Calibration Internal Internal Wear location Thigh Wrist, waist, ankle, and thigh Open in a separate window Specifications of activPAL and ActiGraph GT3X+.

Techniques:

Percent time anatomical posture was coded correctly (±95% CI) and incorrectly (as sitting, standing, or stepping) for each monitor and activity conducted in the laboratory ( n = 21).

Journal: Medicine and science in sports and exercise

Article Title: Ability of Thigh-Worn ActiGraph and activPAL Monitors to Classify Posture and Motion

doi: 10.1249/MSS.0000000000000497

Figure Lengend Snippet: Percent time anatomical posture was coded correctly (±95% CI) and incorrectly (as sitting, standing, or stepping) for each monitor and activity conducted in the laboratory ( n = 21).

Article Snippet: When worn on the thigh, this could contribute to step count inaccuracy if actual step count was an outcome of interest. table ft1 table-wrap mode="anchored" t5 TABLE 1. caption a7 activPAL3 ActiGraph GT3X+ Physical Dimensions 5.3 cm × 3.5 cm × 0.7 cm 4.6 cm × 3.3 cm × 1.5 cm Weight 15 g 19 g Communication Five-port docking station with data transfer port Full-speed USB 2.0 Performance Transducer/sensor Capacitance-based accelerometer Triaxis solid-state accelerometer (ambient light photodiode) Dynamic range ±2 g ±6 g Sample rate 20 Hz 30–100 Hz in 10-Hz increments Resolution 8-bit A/D conversion 12-bit A/D conversion; 2.93 mG (raw data) Memory capacity 16 MB 512 MB Battery life 10 d 30 d (fully charged) Water resistance Can be waterproofed to allow wear in shower 1 m for 30 min Calibration Internal Internal Wear location Thigh Wrist, waist, ankle, and thigh Open in a separate window Specifications of activPAL and ActiGraph GT3X+.

Techniques: Activity Assay

Confusion matrix for synchronized  activPAL  and ActiGraph data during the 3-d free-living protocol ( n = 18).

Journal: Medicine and science in sports and exercise

Article Title: Ability of Thigh-Worn ActiGraph and activPAL Monitors to Classify Posture and Motion

doi: 10.1249/MSS.0000000000000497

Figure Lengend Snippet: Confusion matrix for synchronized activPAL and ActiGraph data during the 3-d free-living protocol ( n = 18).

Article Snippet: When worn on the thigh, this could contribute to step count inaccuracy if actual step count was an outcome of interest. table ft1 table-wrap mode="anchored" t5 TABLE 1. caption a7 activPAL3 ActiGraph GT3X+ Physical Dimensions 5.3 cm × 3.5 cm × 0.7 cm 4.6 cm × 3.3 cm × 1.5 cm Weight 15 g 19 g Communication Five-port docking station with data transfer port Full-speed USB 2.0 Performance Transducer/sensor Capacitance-based accelerometer Triaxis solid-state accelerometer (ambient light photodiode) Dynamic range ±2 g ±6 g Sample rate 20 Hz 30–100 Hz in 10-Hz increments Resolution 8-bit A/D conversion 12-bit A/D conversion; 2.93 mG (raw data) Memory capacity 16 MB 512 MB Battery life 10 d 30 d (fully charged) Water resistance Can be waterproofed to allow wear in shower 1 m for 30 min Calibration Internal Internal Wear location Thigh Wrist, waist, ankle, and thigh Open in a separate window Specifications of activPAL and ActiGraph GT3X+.

Techniques:

Number of transitions per day, by device, during the free-living protocol ( n = 18).

Journal: Medicine and science in sports and exercise

Article Title: Ability of Thigh-Worn ActiGraph and activPAL Monitors to Classify Posture and Motion

doi: 10.1249/MSS.0000000000000497

Figure Lengend Snippet: Number of transitions per day, by device, during the free-living protocol ( n = 18).

Article Snippet: When worn on the thigh, this could contribute to step count inaccuracy if actual step count was an outcome of interest. table ft1 table-wrap mode="anchored" t5 TABLE 1. caption a7 activPAL3 ActiGraph GT3X+ Physical Dimensions 5.3 cm × 3.5 cm × 0.7 cm 4.6 cm × 3.3 cm × 1.5 cm Weight 15 g 19 g Communication Five-port docking station with data transfer port Full-speed USB 2.0 Performance Transducer/sensor Capacitance-based accelerometer Triaxis solid-state accelerometer (ambient light photodiode) Dynamic range ±2 g ±6 g Sample rate 20 Hz 30–100 Hz in 10-Hz increments Resolution 8-bit A/D conversion 12-bit A/D conversion; 2.93 mG (raw data) Memory capacity 16 MB 512 MB Battery life 10 d 30 d (fully charged) Water resistance Can be waterproofed to allow wear in shower 1 m for 30 min Calibration Internal Internal Wear location Thigh Wrist, waist, ankle, and thigh Open in a separate window Specifications of activPAL and ActiGraph GT3X+.

Techniques: